How do I extend my ring main socket

As you can see in the digram, this is done by inserting a longer length of cable between two of the sockets on the existing ring, allowing it to be routed and connected to the new socket on the way. … Fit the new socket box at the required position.

Can you extend a ring main with a junction box?

The best way of using junction boxes to extend a ring circuit, is to find the length of cable between the two sockets on the existing ring closest to the desired extension area. Once located it can be cut in the middle giving two lengths of cable from the existing circuit to use in the extension.

Can I extend a socket ring?

Extending the ring The best method of adding an extra outlet is to extend the ring. This keeps the entire circuit as a ring, avoids overloading at any particular point and keeps two cables in each socket outlet. It may use more cable, and will probably involve additional work if the cables are chased into the wall.

Is extending a ring main notifiable?

extending an existing ring main is considered minor work and a minor works certs is all that required. installing sockets to external building is notifiable.

How many junction boxes can you have on a ring main?

Each socket outlet or junction box on the ring can only have one spur connected. Trying to connect two or more is not only very difficult due to the number of wires involved, it can also result in an abnormally high load at that point in the ring.

How many sockets can a ring main have?

The IET Wiring Regulations (BS 7671) permit an unlimited number of 13A socket outlets (at any point unfused single or double, or any number fused) to be installed on a ring circuit, provided that the floor area served does not exceed 100 m2.

How many sockets can be on a 32a ring main?

There is no limit to the number of sockets you can have on a ring main but there is a limit to the number of spurs you can have from those sockets or from the wiring between them. If you would like to know how to add a spur to an existing ring main, see our project on adding an extra socket.

Can you extend a radial circuit?

The simple answer to this question is yes you can and this is known as a spur, or spurred socket, but there are a few things that you nee to be aware of. You can add one further accessory or socket off of a single socket present in a radial circuit and no more.

Can I use Wago on ring main?

2 Answers. Yes, but a few points need to be observed to make sure it complies with BS7671 IET 17th Edition. Firstly, the terminals must be installed in a Wagobox (when breaking into existing ring wiring).

Do you need Part P to add a socket?

Even simple stuff like moving a socket or adding a spur still comes under part p. This means in order for any electrical work to comply with part p you will need to show the work is safe, a way of doing this would be by being able to show the work complies with 7671.

Article first time published on

Can I use a plug instead of a fused spur?

“The regulations state that the appliance needs to be fused, either with a plug or a fused spur. … So as long as the plug sockets are accessible without touching the appliance to turn it off then this is fine, but also a fused spur is fine too.”

Can you put a double socket on a spur?

A spur can feed one single or one double socket or a fused connection unit.

How much does it cost to fit an extra socket UK?

Plug socket costsCost + VAT (Range low – high)Average costAdding a plug socket to a room cost (USB socket)£65 – £90£77.50Outdoor socket cost£85 – £135£110Installing a plug socket (labour)From £40Moving a socket cost£150

Can you put two circuits in box?

The answer is yes you can have 2 separate circuits in the same box (they can have a splice also but not needed in your case).

Can you put 240v in a junction box?

Can’t do it, not allowed. The junction box cover must be accessible without the use of any tools. (other than the two screws holding on the box cover itself, obviously). However, you can make the junction box be dual-purpose.

Can you overload a ring main?

Because the source is protected by a 30A fuse or 32A breaker, the wiring serving the ring can become overloaded under normal (non-fault) conditions and despite the wiring being overloaded, it being a normal load current and not a fault current means the protective device won’t operate.

How many Spurs can I have on a ring main?

A spur can be connected to an existing socket, on either a ring main or a radial circuit, providing that socket does not already have a spur. That is only one spur per socket is allowed and the number of spurs must not exceed the number of sockets.

Which is better radial or ring circuit?

Ring circuit wiring offered a more efficient and lower cost system which would safely support a greater number of sockets. The lower costs aspect was related to fact that wires with a smaller diameter could be used, compared to radial wiring. … Ring circuits provide low protection against overcurrents.

How many amps can a 2.5 ring main take?

Given 2.5mm twin and earth clipped direct is 27 amps, times two for parallel is 54 amps for a clipped direct, ring.

What is the maximum length of a ring main?

A good rule of thumb for ring finals wired in 2.5mm is that the total length of cable used should preferably not exceed 100m. In certain circumstances a larger total cable length may be admissible, but such circumstances need careful consideration.

Can a single socket be changed to a double?

Replacing a socket or converting a single socket into a double are simple jobs. Sockets can be surface or flush mounted.

Who owns Wago?

Founded in Minden as a family company in 1951, WAGO has been under the long-time guidance of Wolfgang Hohorst, Managing Director with sole power of representation for the WAGO Group.

Do Wagos have to be in a box?

WAGOBOX® Light According to BS 7671, “every connection and termination must be enclosed irrespective of the nominal voltage”. … The WAGOBOX® Light junction box is for use with our 224, 260 and 294 Series connectors.

What are Wagos rated at?

The rating for this compact connector is 400V, 32A. The WAGO 243 series MICRO PushWire connectors are designed for small solid conductors of 0.6mm to 0.8mm diameter. Available in 4 or 8 pole in four different colours, they are very compact yet easy to use.

How many sockets can you have on a 20A Radial?

The number of socket outlets, is unlimited for a floor area of up 20m2 with any type of circuit protection of 20A using 2.5mm2 PVC Copper cable or 1.5mm2 m.i cable. The total number of fused spurs is unlimited.

Can 4mm cable carry 32 amps?

Yes, provided the run is not too long, check volt drop, 4mm is ok on 32 A CB but not on BS 3036 rewireable. Use a 16A commando style plug and socket or hard wire it. “is it ok for a 4mm to go on a 32 amp??” You could probably put the machine on 2.5mm 16amp ctype mcb using a commando plug & socket.

Can you have a 32A radial circuit?

It’s OK to install sockets on a radial circuit using 2.5mm cables protected by a 16A MCB. … 30/32A overcurrent protection device (HBC fuse or circuit breaker) – All live conductors can be wired in 4mm2; however you are restricted to serving a floor area of 75mm2.

Can I have 2 consumer units?

Yes you can fit second consumer unit common when supplying showers and sheds you may have to use two lighting circuits as most light fitting need fusing to 6 amp. There are three ways to connect with henley block or from existing consumer unit and latter with approved cable or twin and earth.

Can I add a second consumer unit?

Long and short of it is yes you can. Making sure that along the way the cabling complies. Dont forget this includes the supply conductors to the secondary board. It is notifiable works.

Can you put a consumer unit outside?

Since regulations changed in 2016, all domestic consumer units must be either enclosed in a non-combustible material or housed in a cabinet made from a non-combustible material. … The rules only apply to consumer units positioned within domestic buildings, so anything installed outside wouldn’t be covered.

Can I rewire my own house?

It is allowed for you to rewire your own house as long as the job can be checked as you go. Most electricans will not agree to these terms as they want to do the whole job.